www.americanlighting.com
WARNING:
These products may represent a possible shock or fire hazard if improperly
installed or attached in any way. Products should be installed in accordance with these
instructions, current electrical codes and/or the current National Electric Code (NEC).
Use this rope light only with LED-NF-CONKIT plug-in power cord. Any other power cord
or feed may damage the fixture. Not intended for hardwire use.
WARNINGS - READ ALL INSTRUCTIONS BEFORE YOU START:
CAUTION - To reduce risk of fire, electric shock or injury to persons, pay close
attention to this manual and stay within its guidelines when using this product.
Before use, note that this product requires an 120V AC outlet. Ensure that the
voltage of your power supply is compatible!
1. Do not cover this product as the covering may cause rope to overheat, melt or ignite.
2. Do not operate LED Neon Flexbrite while it is tightly coiled.
3. Do not submerge flexible light in liquids, or use the product in the vicinity of standing water or other liquids.
4. Do not route the cord or Flexbrite through walls, ceilings, doors, windows or an
y similar part of the building structure.
5. Secure this flexible light using only the mounting clips provided or factory recommended mounting track (sold separately).
6. Do not secure this product or its cord with staples, nails, or like means that may damage the insulation.
7. Do not use if there is any damage to the PVC housing or power cord insulation. Inspect periodically.
8. Do not install on gates or doors, where subject to continuous flexing.
9. Do not install in tanks or enclosures of any kind.
10. Follow instructions carefully when splicing LED Neon Flexbrite sections or attaching power cords. Ensure that all connections,
including the end cap on the last segment, are properly installed with dialectric grease and shrink tube to
preclude the entrance of water (outdoor applications).
11. Risk of fire. Do not replace attachment plug. Discard product if attachment plug is damaged.
12. This product has a polarized plug (one blade is wider than the other) as a feature to reduce the risk of electric shock.
This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does
not fit, contact a qualified electrican. Never use with an extension cord unless plug can be fully inserted. Do not alter plug.
13. LED Neon Flexbrite can only be cut at specific intervals as indicated by the cutting marks printed on the side of the PVC
housing. Failure to cut at a cut mark will result in a loss of light. Before making any cuts or attaching any power cords
or jumpers, be sure power source is disconnected!
14. This product is designed for use by a qualified installer.
15. This product is for decorative use only. Not to be used by children as a toy. Keep out of reach of small children.
16. Do not exceed 150’ maximum run distance in any single run.
Installation instructions for LED-NF and LED-NFPLUS-XX
RV1309
CAUTION - To reduce risk of fire, electric shock or injury to persons:
Do not operate LED Neon
Flexbrite while it is tightly coiled.
WARNING - When using outdoor portable lighting products, basic safety precautions should always
be followed to reduce the risk of fire, electric shock and personal injury, including the following:
2. Use Ground Fault Circuit Interrupter (GFCI) protection on the circuit(s) or outlet(s) when using outdoors.
3. Use only UL approved outdoor extension cords, such as type SW, SOW, STW, STOW, SJW, SJOW, SJTW or
SJTOW. This designation is marked on the jacket of the extension cord.
TO REPLACE FUSE (see Figure 1):
This plug contains an electrical fuse as a safety feature.
1. Disconnect power before replacing the fuse.
2. Grasp plug and remove from the receptacle or other outlet device.
3. Do not unplug by pulling on the cord.
4. Slide open or unscrew the fuse access cover on top of the
attachment plug. See Figure 1.
5. Remove old fuse carefully.
6. Never attempt to replace the fuse with a higher wattage fuse. Use
only 5 Amp 120 Volt fuse. Failure to do so may be
a fire hazard.
7. Set new fuse in holder and reinstall access cover.
1. Use dialectric grease and shrink tube at all power connections including end cap when using outdoors.
Figure 1
Fuse is inside plug. Slide open or
unscrew fuse access cover as shown.
LED Neon Flexbrite, Bulk Reel
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Figure 1

www.americanlighting.comWARNING: These products may represent a possible shock or fire hazard if improperly installed or attached in any w

Page 2 - Figure 2

1. Determine the required length for rope light.2. Cut the Neon Flexbrite squarely at the nearest series increment cut mark using a sharp rope

Modèles reliés LED-NF

Commentaires sur ces manuels

Pas de commentaire